PROJECT TIPS

When preparing for any phase of work on your log home, remember a few simple principles:
- Carefully read all application instructions before you begin.
- Thoroughly clean all work surfaces. Choose your cleaners carefully. Contact
Perma-Chink Systems for complete information.
- Apply products in moderate temperatures, out of direct sunlight.
- Allow all previous applications time to adequately dry before applying another
coat.
- Better tools mean better results - don't skimp.
- Take your time and enjoy the process.
 
Appropriate uses for LIFELINE Products
* NR=Not Recommended
|
Lifeline Ultra-2 |
Lifeline Exterior |
Lifeline Advance |
Lifeline Interior |
Acrylic Gloss |
Acrylic Satin |
Coverage (depends on wood species) |
350-450 sq.ft.
per gallon
first coat; second coat 600-800 sq.ft. per gallon |
350-450 sq.ft.
per gallon;
second coat
600-800 sq.ft.
per gallon |
800-1000 sq.ft.
per gallon over
LIFELINE stain
|
350-450 sq.ft.
per gallon;
second coat
600-800 sq.ft.
per gallon |
500 sq.ft.
per gallon |
500 sq.ft.
per gallon |
Exterior Walls |
2 coats |
2 coats |
multiple coats over LIFELINE stains |
Never |
Never |
Never |
| Soffits |
2 coats |
2 coats |
multiple coats over LIFELINE stains |
Never |
Never |
Never |
| Facia |
2 coats |
2 coats |
multiple coats over LIFELINE stains |
Never |
Never |
Never |
| Decks |
Never |
Never |
Never |
Never |
Never |
Never |
Exterior Trim |
2 coats |
2 coats |
multiple coats over LIFELINE stains |
Never |
Never |
Never |
Interior Walls |
NR |
NR |
NR |
Build thin coats to achieve desired film |
As Desired |
As Desired |
Interior Ceilings |
NR |
NR |
NR |
Build thin coats to achieve desired film |
As Desired |
As Desired |
Interior Millwork |
NR |
NR |
NR |
1 coat to color and seal |
Build thin coats to achieve desired film |
Build thin coats to achieve desired film |
Appropriate use for SEALANTS
NR=Not Recommended
|
Perma-Chink® |
Energy Seal |
Stack-n-Seal |
QSL |
Check Mate® |
Coverage (depends on wood species) |
See table below |
See table below |
See table below |
30 linear ft. per tube |
Variable, depends on check width |
Horizontal Seams |
On Chink-style homes |
After Stacking |
Between logs
During stacking |
NR |
Never |
| Corners |
On Chink-style homes |
External
Sealant |
Internal
Sealant |
NR |
Never |
Windows & Doors |
Energy Seal preferred |
External Sealant |
Internal Sealant |
NR |
Never |
| Butt Joints |
Energy Seal preferred |
External Sealant |
Internal Sealant |
NR |
Never |
Upward Facing Checks |
NR |
NR |
Never |
NR |
Yes |
Kitchen & Bathroom Sealing |
NR |
NR |
Never |
Whenever caulk is needed |
Never |
ESTIMATED COVERAGE RATES
|
Perma-Chink Coverage Rates |
| To be Applied 3/8" - 1/2" thickness. |
| Width of gap | Feet per pail |
| 1/2" | Use Energy Seal |
| 3/4" | Use Energy Seal |
| 1" | 385' |
| 1.5" | 256' |
| 2" | 192' |
| 2.5" | 154' |
| 3" | 127' |
| 3.5" | 110' |
| 4" | 96' |
| 4.5" | 85' |
| 5" | 76' |
| 6" | 63.5' |
|
| Energy Seal Coverage Rates |
| To be applied 3/8" thickness |
| Width of gap | Feet per tube 11-oz. | Feet per tube 30-oz. |
Feet per pail |
| 1/2" | 16' | 48' | 975' |
| 3/4" | 11' | 32' | 650' |
| 1" | 8' | 24' | 490' |
| Stack-n-Seal Coverage Rates |
Diameter of Bead | Feet per tube 11-oz. | Feet per tube 30-oz. |
Feet per pail |
| 1/4" | 32' | 92' | 710' |
| 3/8" | 14' | 41' | 317' |
| 1/2" | 8' | 23' | 178' |
|
Back to top
|